Liquid screed spreads almost entirely under its own weight and reaches a level, smooth surface without the levelling and compaction that a traditional sand and cement screed demands. That is why it has become the default choice for underfloor heating, for large open floor plates and wherever a thin, flat substrate is needed for large format tiles or engineered timber. This guide covers what liquid screed is under BS EN 13318, how calcium sulphate and cement based products differ in composition, the thicknesses and strength classes that apply under BS 8204-7, how long it takes to dry and where it should not be used.

 

Table of Contents

 

What is liquid screed?

Liquid screed is a screed with a flowable consistency that spreads and de-aerates under its own weight. BS EN 13318 defines this category as a screed that can be placed without significant spreading or compaction. That is the fundamental difference from a traditional screed, which contains only enough water for hydration and compaction and has to be raked, tamped and power floated by hand. Liquid screed is pumped through a hose, discharged across the floor and then worked only with a dappling bar to release trapped air and level the surface.

A point worth clearing up early: liquid screed is not a binder type. It describes the consistency. The material itself is classified under BS EN 13813 by its binder, and two families matter in the UK:

  • CA, calcium sulphate screed, commonly called anhydrite or gypsum screed
  • CT, cement based screed, available in both traditional and flowing form

Liquid screed, flowing screed or self-levelling screed?

These three terms describe the same product and are used interchangeably across the UK market. Liquid screed is the most common commercial name, flowing screed is closer to the technical language of BS 8204-7, which refers to pumpable self-smoothing screeds, and self-levelling screed is how most end clients search for it.

The self-smoothing behaviour comes from superplasticisers that fluidise the mix without the excess water that would otherwise be needed. Because the material releases its air when dappled, very few voids remain and the strength is consistent through the full depth rather than concentrated near the surface.

Consistency is a quality criterion, not a matter of preference. It is checked by flow test, and the target spread is set by the product data sheet. A mix that is too stiff will not self-smooth or de-aerate properly. An over-watered mix segregates: the aggregate settles, a weak binder-rich layer is left at the surface, and the drying time stretches well beyond the programme.

 

Installation of an anhydrite-based liquid screed with an in-floor heating system

Installation of an anhydrite-based liquid screed with an in-floor heating system

 

Types of liquid screed

The two families behave differently in shrinkage, moisture resistance and thermal conductivity. Choosing between them is a design decision rather than a preference.

Calcium sulphate (anhydrite) liquid screed

This is the most widely installed liquid screed in the UK. The binder is a form of calcium sulphate: natural anhydrite, synthetic anhydrite, alpha hemihydrate or blends of these. Because of that, the product is sold under several names, including anhydrite screed, gypsum screed and calcium sulphate screed.

Graded sands and limestone aggregates are blended with the binder, together with superplasticisers and, depending on the formulation, further admixtures. The combination produces a dense matrix and high strengths at comparatively low depths.

The defining property of the calcium sulphate binder is its very low shrinkage. Where cement shrinks noticeably as it sets and dries, a calcium sulphate screed remains close to dimensionally stable. That delivers low stress, flat floors, reduced depths and, in most layouts, large bay sizes with few or no movement joints. The trade-off is that the binder is hygroscopic and not moisture resistant.

One characteristic needs planning for: laitance, a thin, weak, binder-rich film that forms at the surface as the screed dries. It slows moisture loss and prevents adhesives from bonding properly, so it has to be removed, usually by light mechanical sanding followed by vacuuming. Some modern formulations are marketed as low-laitance or laitance-free, but the requirement should always be confirmed against the product data sheet and priced as a separate operation.

Cement based liquid screed

Here the binder is cement, combined with graded aggregates and superplasticisers. Many formulations also include polymer or steel fibres to control shrinkage cracking, along with admixtures that reduce water demand.

Cement chemically binds part of the mixing water and the remainder evaporates. Compared with calcium sulphate, a cement based flowing screed shrinks more as it dries, which means greater depths, tighter joint spacing and, in some constructions, reinforcement. In exchange it is moisture resistant, which opens up applications that are closed to calcium sulphate.

Comparison

Property Calcium sulphate liquid screed Cement based liquid screed
Binder Anhydrite, alpha hemihydrate Cement
BS EN 13813 designation CA CT
Shrinkage very low, near dimensionally stable more pronounced, risk of cracking
Required thickness lower higher
Movement joints large bays, few or no joints tighter joint spacing
Moisture resistance not moisture resistant moisture resistant
Thermal conductivity good, well suited to underfloor heating good
Surface preparation laitance removal usually required sanding usually not required
Drying criterion strict RH limit less strict RH limit

📌 Note

Under BS EN 13813 a screed material is designated by binder and strength classes. CA-C25-F5 describes a calcium sulphate screed with a compressive strength of 25 N/mm² and a flexural strength of 5 N/mm². The designation applies to the material as tested in the laboratory, not to the screed as installed on site.

 

How liquid screed is laid: the four constructions

Whatever the binder, liquid screed is installed in one of four basic constructions:

  • Bonded: laid directly onto a prepared substrate with a primer or bonding agent, so loads pass straight into the slab. Used where build-up height is critical and point loads are high.
  • Unbonded: separated from the substrate by a membrane. Suited to existing slabs that are cracked, damp or of uncertain quality, because stresses and moisture are not transmitted into the screed.
  • Floating: laid over insulation and isolated at the perimeter, giving thermal and acoustic separation. This is the standard domestic build-up.
  • Underfloor heating: the screed fully encapsulates the heating pipes.

Liquid screed is also used as the structural topping on raised access and void floors, where its placing rate and dimensional stability suit large commercial floor plates.

 

Advantages and disadvantages of liquid screed

Advantages

  • Flat, level surface with no hand finishing. The surface finds its own level, which matters most under large format tiles and thin floorcoverings.
  • Very high placing rates. Large areas are covered quickly because the material is distributed through a hose rather than barrowed and raked.
  • Consistent strength through the depth. Self-compaction removes the voids that collect in the lower layers of a hand-laid screed.
  • Physically far less demanding to install. No tamping, no power floating.
  • Reduced build-up height. Calcium sulphate products in particular can be laid thinner than a traditional screed of equivalent performance.
  • Complete encapsulation of heating pipes, with no air pockets around the circuit.
  • Large bays with few joints, especially with calcium sulphate binders.

Disadvantages

  • Mechanical installation is essential. Without a mixing plant, a pump and a trained gang, liquid screed is not a viable option.
  • Unforgiving of site errors. Over-watering, a poorly sealed membrane or a missing edge strip all show up directly in the finished floor.
  • More demanding preparation. The membrane over the insulation has to be sealed well enough that no liquid material can escape into the layers below.
  • Moisture sensitivity of calcium sulphate products, which restricts where they can be used.
  • Laitance removal on most calcium sulphate screeds is an extra operation that needs to be programmed and priced.
  • Falls cannot be formed. The material always finds a horizontal plane.

 

Liquid screed thickness and load-bearing capacity

Required thickness is not a property of the material alone. It follows from the construction type, the imposed loads, the flexural strength class and, in floating floors, the compressibility of the insulation below. BS 8204-7 is the governing code of practice, and every manufacturer publishes depths for its own product.

Typical depths for calcium sulphate liquid screed in domestic and light commercial work:

Construction Typical thickness
Bonded from around 25 mm
Unbonded from around 30 mm
Floating, domestic loading from around 35 mm
Floating, commercial loading from around 40 mm
Over underfloor heating pipes minimum 30 mm cover above the pipe

Cement based flowing screeds generally require greater depths than the figures above, because of their higher shrinkage.

There is no normative upper limit, but there is a practical one. As depth increases, self-weight, material volume and above all drying time rise disproportionately, because moisture has further to travel to reach the surface. Significant level differences are better resolved with a lightweight subfloor below the screed, with the liquid screed then laid at its normal depth on top.

Load-bearing capacity itself is expressed through the BS EN 13813 strength classes: C for compressive strength and F for flexural strength, both in N/mm². Domestic floors are commonly specified around C25-F5, with higher classes where imposed loads increase.

 

Liquid screed drying times

Drying means losing the mixing water that was not chemically bound. Three separate milestones matter on site, and they are frequently confused with one another.

Stage Calcium sulphate liquid screed Cement based liquid screed
Light foot traffic after around 24 to 48 hours after around 48 hours
Taking site loads after around 5 to 7 days after around 7 days
Ready for floorcoverings subject to RH test, typically several weeks subject to RH test, typically longer
Moisture limit, general floorcoverings ≤ 75% RH ≤ 75% RH
Moisture limit, timber floorcoverings ≤ 65% RH ≤ 65% RH

As a planning rule of thumb, a liquid screed dries at roughly 1 mm per day for the first 40 mm, and considerably more slowly beyond that depth. A 50 mm screed therefore takes far longer than the first 40 mm would suggest, which is the single most common cause of programme slippage on this trade.

Drying only happens if the building allows it. Ambient temperature of around 20 °C, relative humidity below 65% and regular air changes are the conditions those figures assume. Removing laitance early also matters, because the film slows moisture loss while it remains in place.

📌 Note

A screed is ready for floorcoverings when it is measured as ready, not when the programme says so. In the UK this is confirmed by a relative humidity test to BS 8203, using a surface hygrometer left in place until the reading stabilises. Hand-held electrical moisture meters give an indication only and do not constitute a release test.

 

Where liquid screed is used (and where it isn’t)

Liquid screed earns its place wherever large continuous floor areas have to be laid quickly and flat. Typical applications are housing and apartment schemes, offices and commercial fit-outs, public buildings, and refurbishment work where build-up height is tight. It is particularly common in combination with underfloor heating and as a substrate for large format tiles, engineered timber and thin resilient floorcoverings, all of which depend on a flat base.

The limits come mainly from the binder. Calcium sulphate products are confined to dry internal areas. Where water vapour or ground moisture is expected, a damp proof membrane or tanking system has to be specified separately by the designer. Cement based flowing screeds are less sensitive and cover applications that are closed to calcium sulphate.

Liquid screed is also the wrong choice wherever falls are required, and on slabs with a pronounced existing slope, since the material will level out the difference and the depth at the low point grows accordingly. Small, heavily subdivided areas rarely justify the plant involved.

 

Liquid screed or sand and cement screed?

There is no single answer, because the two options are strong in different places. Liquid screed wins on flatness, placing rate, consistency of strength through the depth and pipe encapsulation. Traditional sand and cement screed is more flexible on small areas, allows falls to be formed, introduces less water into the building and can be laid without a pump and mixing plant.

On any given project the deciding factors are area, intended floorcovering, build-up height, exposure to moisture and programme. A broader overview of all screed types is set out in the complete screed guide.

Sand and cement screed vs self-levelling screed

 

Liquid screed for underfloor heating

Underfloor heating is where liquid screed shows its clearest structural advantage. Because the material flows and releases its own air, it encapsulates the pipework without voids. Air pockets beneath or beside a pipe, which can survive even careful compaction in a traditional screed, act as insulation at precisely the point where heat is supposed to transfer.

Full encapsulation raises the effective thermal conductivity of the build-up. That allows lower flow temperatures for the same output, which matters most when the system runs from a heat pump, and produces more even floor surface temperatures. The reduced depth possible with calcium sulphate products also lowers the thermal mass, so the floor responds faster to control inputs.

Additional rules apply to the installation. A minimum 30 mm cover above the pipe is normally required, the circuits must be pressurised and proven before the pour, and a documented commissioning and force drying regime has to be completed before any floorcovering goes down.

Underfloor heating screed: build-up and depth

 

How liquid screed is mixed and laid

Preparation comes first. The substrate is cleaned and cleared of mortar droppings and loose material, and significant irregularities are corrected before anything else goes down. Perimeter edge strip, typically at least 8 mm thick, is fixed to all walls, columns and door frames, running from the structural base to the top of the finished floor and only trimmed once the floorcovering is complete. On floating constructions the insulation follows, then a sealed membrane with lapped and taped joints. That membrane is not a detail: if liquid material escapes into the insulation, it forms acoustic bridges that cannot be corrected afterwards.

The material itself reaches the floor by one of two routes. Either bagged or silo-supplied dry mortar is mixed with water on site, or the screed is batched on site from raw components, combining aggregate, binder, water and admixtures. On larger areas the second route is the more economic and allows the mix to be matched to the job.

In both cases the accuracy of the water dosing governs the result. Sand carries its own moisture, which varies with stockpile and weather, so a fixed water addition produces a different consistency from batch to batch. The symptoms are inconsistent flow across one floor, variable strength and uneven, extended drying.

During the pour, the discharge hose is swept steadily back and forth so the mix does not segregate. Dropping the hose in the middle of the room and waiting for the floor to find its own level produces the opposite of the intended result. Once the design depth is reached, the surface is worked immediately with a dappling bar, firmly in one direction and then more lightly across it. The resulting wave action releases entrained air and levels the surface.

For the first few days the new screed is protected from draughts, direct sunlight, heat and frost. Only after that does the active drying phase begin, with controlled ventilation.

 

Overmat machines for liquid screed

Much of the quality of a liquid screed is decided before the hose, at the mixer. Consistency, strength and drying time all depend on how accurately aggregate, binder, water and admixtures are dosed, and how repeatable the result is from batch to batch.

Overmat, an Italian manufacturer of automated mixing and pumping plant based in Colle Umberto (TV), automates exactly that stage. The ALS Series liquid screed machines batch anhydrite and cement based liquid screed directly on site. A probe continuously measures the moisture content of the sand, and the on-board computer corrects the water volume for every batch, holding the flow value steady without anyone adjusting by eye. The system doses aggregates of different gradings, binders, liquid, gel and powder admixtures, and fibres. Output reaches up to 12 m³/h, and every batch is recorded and retrievable through the on-board data connection.

For cement based mixes the ALS Series is also available with a split binder silo, carrying cement and filler separately so each can be dosed precisely. Where pre-mixed material is used instead, the A Series covers that requirement and also produces lightweight subfloors in foamed concrete and polystyrene, which is the better answer where large level differences have to be made up. The 22 A PTO model carries two independent binder compartments and can produce both products on the same day. Where traditional sand and cement screed is also required on the same site, the TWIN Series combines both processes in a single plant.

Production data and machine status can be monitored remotely in real time through the MixerApp, which simplifies batch records and remote support when something needs attention.

 

FAQ

What is the difference between liquid screed and self-levelling compound?

Liquid screed is a load-distributing layer, typically 25 to 40 mm or more, laid bonded, unbonded, floating or over underfloor heating and designed under BS 8204-7. Self-levelling compound, also called levelling or smoothing compound, is a thin correction layer of a few millimetres applied over an already sound substrate to take out minor irregularities before the floorcovering goes down. Both are self-levelling, which is where the confusion comes from, but a compound cannot replace a screed and carries no load in its own right.

Can liquid screed be polished?

Liquid screed is designed as a substrate for a floorcovering, not as a wearing surface. It can be ground, sanded and sealed to give an exposed decorative finish, and that is occasionally done, but the result is not comparable to a polished concrete floor in durability. Calcium sulphate products are the weaker candidate because of their moisture sensitivity, so cement based flowing screeds are the better starting point. In every case the manufacturer has to confirm that the product is suitable for exposure and specify an appropriate sealer.

How soon can liquid screed be laid over a new concrete slab?

For a bonded screed the slab must have gained adequate strength and stopped the bulk of its early shrinkage, which in practice means waiting until it is properly cured, commonly around 28 days. For unbonded and floating constructions the wait is shorter, because the membrane separates the two layers, but the slab still needs an effective damp proof membrane below the screed. Residual moisture rising from a young slab is the most common cause of failure with calcium sulphate products.

Does liquid screed need sanding?

Most calcium sulphate screeds do. The laitance that forms at the surface while the screed dries is weak, slows moisture loss and stops adhesives bonding properly, so it is removed by light mechanical sanding followed by vacuuming, usually within the first week or two once the floor takes foot traffic. The earlier it is done, the faster the screed continues to dry. Some low-laitance products are exempt, and cement based flowing screeds generally do not need it, but the product data sheet is the deciding document and the operation should be priced separately.

Can liquid screed be used outside, and is it waterproof?

Calcium sulphate liquid screed is not suitable for external use, because the binder is moisture sensitive and will lose strength in wet exposure. Cement based flowing screeds are more robust, but external use requires explicit confirmation from the manufacturer. There is also a practical obstacle: external areas need falls, and a self-smoothing screed cannot form them. No screed of any type is waterproof in itself, and waterproofing is always a separate layer in the build-up.

Is calcium sulphate liquid screed suitable for bathrooms and wet rooms?

In a domestic bathroom it can be used, provided a tanking or waterproofing system above the screed protects it permanently from water reaching the surface, typically under a tiled finish. In wet rooms, commercial kitchens, swimming pools and similar continuously wet environments it is ruled out, and a cement based screed should be specified instead. The waterproofing strategy is a design decision and needs to be set out by the specifier rather than resolved on site.

Which type of liquid screed is best?

There is no universally better option. In dry internal areas, where build-up height is tight and underfloor heating is involved, calcium sulphate is usually the stronger choice: low shrinkage, thinner depths, large bays with few joints. Where moisture is a factor, the answer is a cement based flowing screed. The decision follows from the use of the space, the exposure to moisture, the intended floorcovering and the depth available.

Can liquid screed be laid over an existing screed, timber or tiles?

Over a sound, dry and crack-free existing screed, yes: renovating old anhydrite floors is a standard application, with the surface cleaned, sanded and primed as required. Existing tiles can work if they are firmly bonded and properly prepared, otherwise an unbonded construction over a membrane is the safer route. Timber substrates are a different matter, because the added weight has to be checked against the joists and the screed must be fully isolated from the timber. In all three cases the condition and structural capacity of the existing floor need assessing before anything is specified.

What machine is needed to lay liquid screed?

Liquid screed requires a mixing and pumping plant that produces the mortar at a consistent flow value and delivers it through a hose to the point of placement. Accurate dosing of water, binder, aggregate and admixtures is what makes the difference, because small deviations change flow, strength and drying time. Our guide to the liquid screed machine covers what to look for, and the ALS Series automates the whole batching sequence, correcting the water volume from the measured sand moisture on every load.